Füllstand - ZIMMERLI MESSTECHNIK AG

eclipse706_t
  • GWR (guided wave radar) high performance level transmitter
  • Measurement of low epsilon values possible (Er ≥ 1,4)
  • Volumetric measurement
  • Probe with quick coupling
  • Works with visible vapours and unaffected by most foams
  • Approval for IS- (intrinsically safe), XP- (pressure-resistant encapsulated), and non-sparking applications
  • Unaffected by build-up
eclipse_705_hygienic_t
  • GWR (guided wave radar) level transmitter
  • Electronic 2-wire measuring transducer with 24 V DC and 4-20 mA
  • Suitable for “dry test procedure” for additional cost savings
  • Probe version for CIP and SIP cleaning
  • 0.1 % Measuring range accuracy
  • 0.025 % Volume reproducibility
  • Meets EHEDG requirements
eclipse_705_t
  • GWR (guided wave radar) level transmitter
  • Measurement of low epsilon values possible (Er ≥ 1,4)
  • Volumetric measurement
  • Probe with quick coupling
  • Works with visible vapours and unaffected by most foams
  • Approval for IS- (intrinsically safe), XP- (pressure-resistant encapsulated), and non-sparking applications
  • Unaffected by build-up
aurora_side
  • GWR (guided wave radar) magnetic level indicator
  • Measurement of low epsilon values possible (Er ≥ 1,4)
  • Volumetric measurement
  • Probe with quick coupling
  • Works with visible vapours and unaffected by most foams
  • Approval for IS- (intrinsically safe), XP- (pressure-resistant encapsulated), and non-sparking applications
  • Unaffected by build-up
  • With overfill protection
  • Two completely independent integrated system creates a completely redundant system
  • No adjustment is required for either of the measuring systems
  • Electronic 2-wire measuring transducer in accordance with EEx ia
r86
  • 26 GHz non-contact radar transmitter
  • Process independent performance
  • Operating frequency of 26 GHz for outstanding performance in accuracy and resolution.
  • Antenna versions up to +400 °C
  • Measuring range up to 40 m.
  • The antenna with quick coupling allows the container to remain closed
  • Available for use in the SIL-2 measurements chains (93.2% SFF, full FMEDA report available)
  • PACTware™ PC programme and improved DTMs
r82
  • Non-contact radar pulse burst radar transmitter
  • Electronic 2 wire transducer in intrinsically safe design
  • Frequency of 26 GHz
  • Quick and simple configuration with the aid of a two-line display with 16 characters each and four operating keys
  • Intuitive determination of false target profiles
  • Rotatable microwave beam for optimised operation
  • Encapsulated antennas made of polypropylene or Tefzel® in lengths of 50 mm and 200 mm
  • Process temperature: -40 °C up to +93 °C
  • Pressure: Vacuum up to 13.8 bar
  • Epsilon: 1.7 – 100
R96
  • Non-contact radar transmitter
  • Operating frequency of 6 GHz
  • Electronic 2-wire measuring transducer in accordance with EEx ia.
  • User interface with four buttons and graphic LCD-
  • Two antenna versions up to +200 °C/51.7 bar
  • Measuring range up to 40 m.
  • False target set-up is simple, intuitive and effective.
  • Suitable for SIL1 and SIL2 measurement chains
  • Can automatically record the envelope on an incident or error .
ThermatelTD1_2Hygienic
  • Thermal mass flow limit switch
  • Suitable for SIL2 measurement chains
  • Meets EHEDG requirements
  • Tri-Clamp®, DIN 11851, Varivent®
  • LED display of alarm status and errors
  • Sensor designed for CIP/SIP cleaning
thermatel_tg1_t
  • Thermal mass flow limit switch
  • The flow rate can be read via the LEDs
  • Electronic 2-wire measuring transducer in accordance with EEx ia.
  • Non-linear mA output signal can be used for trending, diagnostics and repeatable flow/level display
  • Switching point and time delay adjustable on site
  • SPDT alarm relay
  • Permanent diagnosis for the determination of sensor malfunctions
Thermatel TD1_2
  • thermal mass flow limit switch for flow, level and layers
  • Permanent diagnosis for the determination of sensor malfunctions
  • Non-linear mA output signal can be used for trending, diagnostics and repeatable flow/level display
  • Determines the minimum flow or presence/absence of flow
Echotel 961 Hygienic
  • Ultrasound level switch
  • SIL1 and SIL2 measurement chains
  • Meets EHEDG requirements
  • Adjustable time delay for turbulent liquids
  • Tri-Clamp®, DIN 11851, Varivent®
  • LED display of alarm status and errors
  • Sensor designed for CIP/SIP cleaning
echotel_961_962
  • Ultrasound level switch
  • Suitable for SIL2 measurement chains
  • no configuration necessary
  • Adjustable time delay for turbulent liquids
  • Advanced diagnosis: Sensor, electronic and noise
  • LED display of alarm status and errors
  • Metal and plastic sensors
echotel_910
  • Ultrasound level switch for liquids
  • DPDT relay
  • Fail-safe mode selectable on site
  • No adjustment necessary
  • Measuring transducer made of stainless steel 316
  • Minimum sensor length of 30 mm