Füllstand - ZIMMERLI MESSTECHNIK AG

eclipse706_t
  • GWR (guided wave radar) high performance level transmitter
  • Measurement of low epsilon values possible (Er ≥ 1,4)
  • Volumetric measurement
  • Probe with quick coupling
  • Works with visible vapours and unaffected by most foams
  • Approval for IS- (intrinsically safe), XP- (pressure-resistant encapsulated), and non-sparking applications
  • Unaffected by build-up
eclipse_705_hygienic_t
  • GWR (guided wave radar) level transmitter
  • Electronic 2-wire measuring transducer with 24 V DC and 4-20 mA
  • Suitable for “dry test procedure” for additional cost savings
  • Probe version for CIP and SIP cleaning
  • 0.1 % Measuring range accuracy
  • 0.025 % Volume reproducibility
  • Meets EHEDG requirements
eclipse_705_t
  • GWR (guided wave radar) level transmitter
  • Measurement of low epsilon values possible (Er ≥ 1,4)
  • Volumetric measurement
  • Probe with quick coupling
  • Works with visible vapours and unaffected by most foams
  • Approval for IS- (intrinsically safe), XP- (pressure-resistant encapsulated), and non-sparking applications
  • Unaffected by build-up
aurora_side
  • GWR (guided wave radar) magnetic level indicator
  • Measurement of low epsilon values possible (Er ≥ 1,4)
  • Volumetric measurement
  • Probe with quick coupling
  • Works with visible vapours and unaffected by most foams
  • Approval for IS- (intrinsically safe), XP- (pressure-resistant encapsulated), and non-sparking applications
  • Unaffected by build-up
  • With overfill protection
  • Two completely independent integrated system creates a completely redundant system
  • No adjustment is required for either of the measuring systems
  • Electronic 2-wire measuring transducer in accordance with EEx ia
r86
  • 26 GHz non-contact radar transmitter
  • Process independent performance
  • Operating frequency of 26 GHz for outstanding performance in accuracy and resolution.
  • Antenna versions up to +400 °C
  • Measuring range up to 40 m.
  • The antenna with quick coupling allows the container to remain closed
  • Available for use in the SIL-2 measurements chains (93.2% SFF, full FMEDA report available)
  • PACTware™ PC programme and improved DTMs
r82
  • Non-contact radar pulse burst radar transmitter
  • Electronic 2 wire transducer in intrinsically safe design
  • Frequency of 26 GHz
  • Quick and simple configuration with the aid of a two-line display with 16 characters each and four operating keys
  • Intuitive determination of false target profiles
  • Rotatable microwave beam for optimised operation
  • Encapsulated antennas made of polypropylene or Tefzel® in lengths of 50 mm and 200 mm
  • Process temperature: -40 °C up to +93 °C
  • Pressure: Vacuum up to 13.8 bar
  • Epsilon: 1.7 – 100
R96
  • Non-contact radar transmitter
  • Operating frequency of 6 GHz
  • Electronic 2-wire measuring transducer in accordance with EEx ia.
  • User interface with four buttons and graphic LCD-
  • Two antenna versions up to +200 °C/51.7 bar
  • Measuring range up to 40 m.
  • False target set-up is simple, intuitive and effective.
  • Suitable for SIL1 and SIL2 measurement chains
  • Can automatically record the envelope on an incident or error .
ThermatelTD1_2Hygienic
  • Thermal mass flow limit switch
  • Suitable for SIL2 measurement chains
  • Meets EHEDG requirements
  • Tri-Clamp®, DIN 11851, Varivent®
  • LED display of alarm status and errors
  • Sensor designed for CIP/SIP cleaning
thermatel_tg1_t
  • Thermal mass flow limit switch
  • The flow rate can be read via the LEDs
  • Electronic 2-wire measuring transducer in accordance with EEx ia.
  • Non-linear mA output signal can be used for trending, diagnostics and repeatable flow/level display
  • Switching point and time delay adjustable on site
  • SPDT alarm relay
  • Permanent diagnosis for the determination of sensor malfunctions
Thermatel TD1_2
  • thermal mass flow limit switch for flow, level and layers
  • Permanent diagnosis for the determination of sensor malfunctions
  • Non-linear mA output signal can be used for trending, diagnostics and repeatable flow/level display
  • Determines the minimum flow or presence/absence of flow
Echotel 961 Hygienic
  • Ultrasound level switch
  • SIL1 and SIL2 measurement chains
  • Meets EHEDG requirements
  • Adjustable time delay for turbulent liquids
  • Tri-Clamp®, DIN 11851, Varivent®
  • LED display of alarm status and errors
  • Sensor designed for CIP/SIP cleaning
echotel_961_962
  • Ultrasound level switch
  • Suitable for SIL2 measurement chains
  • no configuration necessary
  • Adjustable time delay for turbulent liquids
  • Advanced diagnosis: Sensor, electronic and noise
  • LED display of alarm status and errors
  • Metal and plastic sensors
echotel_910
  • Ultrasound level switch for liquids
  • DPDT relay
  • Fail-safe mode selectable on site
  • No adjustment necessary
  • Measuring transducer made of stainless steel 316
  • Minimum sensor length of 30 mm
Zimmerli Messtechnik AG Logo
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.