High pressure
0 to 1000 bar

Medium pressure
0 to 40 bar

Low pressure
-1000 to 2500 mbar

Do you have any question?
GS_RAMC
  • wetted parts made of stainless steel or PTFE
  • Modular design: mechanical display, 4…20mA/HART®7, FF, Profibus-PA and summator
  • Flange: DN15…150 / ½…6″; also NPT, G, hygiene connections etc.
  • -196…+400°C; max. 1000 barg
GS_RAKD
  • Compact mechanical display, optional 4…20mA, MIN/MAX contacts and needle valve
  • Robust metal construction: Stainless steel 316Ti
  • Thread: G¼, ¼ NPT, Flange DN15…25 / ½»…1″
  • -40…+250°C, max. 250 barg
GS_RAGL
  • Simply and quick exchange of the glass measuring tubes, valve and MIN/MAX contacts
  • For low flows: Water 0.002 l/h – 630 l/h or air: 0.2 l/h – 6300l/h
  • G- and NPT threads
  • -20°C…+130°C; max. 16 barg
  • Measuring range ratio: ≈10:1 and ≈20:1
RAGK
  • Selectable with and without valve and limit switch
  • For low flows: Water 0.002 l/h – 630 l/h or air: 0.2 l/h – 6300l/h
  • -20°C…+130°C; max. 16 barg
  • Measurement accuracy: 2.5%…4%
RAGN
  • Complete stainless steel design
  • With glass cone MIN/MAX contacts according to SIL
  • Low pressure loss in gas applications
  • Flange: DN15…50 / ½…2″; also NPT- and G connections
  • -20…+100°C; max. 10 barg
RotamassTI-Nano
  • Maximum mass flow 1.5 t/h @ 
  • Measurement accuracy: +/- 0,1 % liquid, +/- 0.35 % gases, +/- 0.5 g/l density
  • Process temperature:-50 to +260°C
  • Process pressure up to 460 bar
  • Nominal diameter: DN 15 up to DN 125, 1/4 up to1 ½ inches
  • Approvals: SIL2 (SIL 3), ATEX, etc.
RotamassTI-Prime
  • Maximum mass flow 255 t/h @ 
  • Measurement accuracy: +/- 0,1 % liquid, +/- 0.35 % gases, +/- 0.5 g/l density
  • Process temperature:-70 to +200°C
  • Process pressure up to 100 bar
  • Nominal diameter: DN 15 up to DN 125, 3/8 up to 5 inches
  • Approvals: SIL2 (SIL 3), ATEX, etc.
RotamassTI-Supreme
  • Maximum mass flow 170 t/h
  • Measurement accuracy: +/- 0,1 % liquid, +/- 0.35 % gases, +/- 0.5 g/l density
  • Process temperature:-196 to +150°C
  • Process pressure up to 360 bar
  • Nominal diameter: DN 15 up to DN 125, 3/8 up to 5 inches
  • Approvals: SIL2 (SIL 3), ATEX, etc.
RotamassTI-Intense
  • Maximum mass flow 50 t/h
  • Measurement accuracy: +/- 0,1 % liquid, +/- 0.35 % gases, +/- 0.5 g/l density
  • Process temperature:-70 to +350°C
  • Process pressure up to 180 bar
  • Nominal diameter: DN 15 up to DN 50, 4 up to 8 inches
  • Approvals: SIL2 (SIL 3), ATEX, etc.
RotamassTI-Hygienic
  • Maximum mass flow 76 t/h
  • Measurement accuracy: +/- 0,1 % liquid, +/- 0.35 % gases, +/- 0.5 g/l density
  • Process temperature: -70 up to +150°C
  • Certificates: 3-A- or EHEDG application
  • Nominal diameter/clamp connections: DN 25 up to DN 80, 1 up to 3 inches
  • DIN11864, DIN11851, DIN32676, etc
  • Approvals: SIL2 (SIL 3), ATEX, etc.
RotamassTI-Giga
  • Maximum mass flow 600 t/h
  • Measurement accuracy: +/- 0,1 % liquid, +/- 0.35 % gases, +/- 0.5 g/l density
  • Process temperature: -70 up to +150°C
  • Process pressure up to 250 bar
  • Nominal diameter: DN 15 up to DN 50, 3/8 up to 2 inches
  • Approvals: SIL2 (SIL 3), ATEX, etc.
YEWFLO DY
  • High temperature version up to 450°C
  • Low temperature version at least -196°C
  • 2-wire, 4…20 mA, HART®
  • Flange: DN15…400 / 1/2″…16″, max. PN160 / ASME 1500 lb
  • High accuracy,
    • ±0.75 % of the measured value (liquid)
    • ±1.0 % of the measured value (gas, vapour)
  • SSP accurately detects eddies in the low flow range and provides excellent flow measurement stability
ADMAG-AXR
  • Accuracy ± 0.25 %
  • Conductivity >1μS/cm
  • Liner Material: PTFE, PU, rubber (soft/hard)
  • Size: DN 25 up to DN 100
  • Electrode adhesion detection, sensor empty test
  • For general processes, especially for water as well as corrosive and abrasive liquids
  • Explosion protection according to IECEx, ATEX, etc.
ADMAG AXG
  • High accuracy ± 0.15 %, standard ± 0.3%
  • Conductivity >1μS/cm
  • Liner Material: Ceramic, PFA
  • Size: DN 2.5 up to DN 500
  • Flow noise and conductivity diagnosis
  • Electrode adhesion detection, sensor empty test
  • Ideal for processes that handle many strongly corrosive and abrasive liquids
  • Explosion protection according to IECEx, ATEX, etc.
ADMAG AXW
  • Measures the flow in processes with large diameters
  • Accuracy ± 0.35 %
  • Liner Material: PTFE, PU, rubber (soft/hard)
  • Size: DN 25 up to DN 1800
  • Electrode adhesion detection, sensor empty test
  • For general processes, especially for water as well as corrosive and abrasive liquids
  • Explosion protection according to IECEx, ATEX, etc.
EJX_910A_930A
  • Mass flow measurement:
  • Orifice plates, nozzles or venturi tubes are supported as differential pressure transducers
  • The HART-7 protocol also supports dynamic pressure probes and v-cone gauges
  • The accuracy is ±1.0 % v. M. of the mass flow
  • Fully compensated mass flow values
  • Mass flow meter with ±1.0 % accuracy
  • Pulse/contact output
  • 4500 psi maximum operating pressure
  • TÜV certification SIL 2/SIL 3
TA2
  • Direct mass flow measurement of air and gases.
  • Pressure or temperature compensation
  • High turndown rate of 100:1.
  • Excellent low-flow sensitivity.
  • Low pressure loss.
  • Calibration with ISO 17025 and NIST certificate.
  • Process temperature up to +200 °C.
  • Process pressure up to 103 bar, depending on process connections.
  • ATEX / IEC approvals
  • Suitable for SIL1- and SIL2
Thermatel TD1_TD2
  • Simple adjustment on site - factory adjustment possible on request
  • Process conditions up to +450 °C and 414 bar.
  • Determination of variable flow or flow/no flow for gases and liquids.
  • Excellent “low-flow” sensitivity.
  • Automatic temperature compensation for repeatable
  • alarm under different process temperatures.
  • Permanent diagnosis for the determination of sensor malfunctions.
  • Process pressure up to 103 bar, depending on process connections.
  • ATEX / IEC approvals
  • Suitable for SIL1- and SIL2
deltaflow
  • Lower pressure loss, thus lower energy losses
  • Simple installation, no disconnecting of the pipeline necessary
  • Lighter weight even with large diameters
  • Very high accuracy (deltaflow from 0.4%)
  • Very high measurement dynamics, depending on application up to 1:30
  • Higher insensitivity to dirt and condensates
  • Low procurement costs even with large diameters
  • Proven basics. Flow measurement is made with the deltaflow dynamic pressure probe along the same principles as with the classical primary elements (orifice, venturi, nozzle), the integration into the measurement computer or the process control system thus works
deltawaveC-P
  • integrated heat quantity measurement, 1,2 and 4 channel
  • Pipe sizes DN10…DN6000 (DN25…DN500 for gases)
  • Non-contact assembly (clamp on)
  • Measuring range: -30…30 m/s
  • Measured parameters: Flow, flow rate, thermal output
  • Inputs: 2 x PT100, 2 x 4..20 mA
  • Outputs: 1 x relay 2 x 4…20 mA, 2 x digital
  • Interface: RS232, RS485, Modbus, M-Bus
  • Interface: USB
  • Medium: Liquids
  • Temperature: -70…150°C, optional -50…380°C
ELETTA_collage
  • 4-20 mA Output signal combined with local display economical alternative to more expensive flow meters
  • Use in the same line sections as with other Eletta
  • flow monitors• measures with +/- 5% accuracy • both liquids and gases can be monitored